Minimising Line Losses in RE Systems



Minimising Line Losses In RE Systems

Select wire of the correct diameter for your renewable energy system

storage | electric circuit
Printer Friendly Version Print Article     

In most renewable energy systems low voltage DC (direct current) electricity is generated. When this is from a wind turbine generator or a hydro electricity generator there is usually quite a distance between the location of the generator and the battery bank or power inverter.

If the wire (cable) taking this electricity is not thick enough you may potentially lose vast amounts of expensively generated power in resistive line losses - basically speaking, you will be heating the wire rather than charging your batteries. However, with the recent jump in the price of copper, if you choose wire which is unnecessarily thick, the extra costs incurred will seriously get in the way of your generating free (not that such a thing exists) electricity.

In an ideal situation line losses should be kept at or below 10% - i.e. no more than 10% of the power you generate should be lost in the wires you use to transmit it to your battery bank or inverter.

What You Need to Know to Calculate Line Losses

Calculating your likely line losses is quite a simple process requiring no more than a standard calculator and a little knowledge - supplied here.

NOTE - If you are not interested in the mathematics then scroll down to the final equations so you can start making some calculations for your system.
NEW You can also click here to go to our new Line Losses Calculator which will automatically calculate the size of wire you require for your system, or calculate the line losses for a given wire size.

The one constant you need is the resistivity of copper (rho) = 0.000000017 Ohms per metre at 20 degrees Celcius.

You should know the charging voltage (peak) and current (peak) of your generator. The charging voltage is always higher than the rated voltage of a generator - e.g. a 12 Volt solar panel will actually have an open circuit voltage of at least 18 Volts. You need to use the higher value in your calculations.

The cross-sectional area of your wire is given by multiplying the radius (half the diameter) of the wire squared by PI (3.14159).

If the wire is made up of multple strands then the cross-sectional area is given by squaring the radius of one strand and multiplying it by PI and then by the number of strands.

Once you know these values you are ready to calculate the resistance of your power lines and therefore your power losses.

Calculating Line Losses

The resistance of a length of wire is equal to 1,000,000 multiplied by the length of the wire (in metres) multiplied by rho and then divided by the cross sectional area of the wire (in square mm). Note that 1,000,000 square mm is equal to one square metre - hence the factor of 1,000,000 in the equation.

For example:
A wire 200 metres long with a cross sectional area of 2.25 square mm has a resistance of:
(1,000,000 * length * 0.000000017) / 2.25 = 1.51 ohms

The power loss is given by the square of the current in amps multiplied by the resistance of the wire, so with a 30 amp peak power output wind turbine generator and the example wire above, the power loss is:
30 * 30 * 1.51 = 1,359 Watts

If the example wind turbine has a charging voltage of 65 volts (typical of a 48 Volt rated wind turbine) then the peak power output of this wind turbine would be equal to the charging voltage multiplied by the current = 65 x 30 = 1,950 Watts.

Therefore of the 1.95kW generated by the wind turbine, 1.36kW would be lost as line losses = 70%!
100 * 1.36/1.95 = 70%

Using the Equation to Select wire for Your System

All the mathematics above can be simplified into one easy (relatively) equation:

Power Loss (%) =
1.7 * Current * Wire Length
Charging Voltage * Wire Area

In order to choose wire for your own renewable energy system you just need to choose the amount of line losses you are willing to accept (e.g. 10%), feed the numbers into the equation below, and out comes the minimum cross-sectional area of wire you will need.

Wire X-Sectional Area =
1.7 * Current * Wire Length
Charging Voltage * Power Loss %

So with the example 48V wind turbine generator which had a 65 Volt charging voltage and 30 amp maximum current, a 200 metre run of wire required, and no more than 10% line losses acceptable - wire with a cross sectional area of 15.7 square mm is required:
(1.7 * 30 * 200) / (65 * 10) = 15.7 sq.mm

Looking at the wires available on the market around this size there is 6 AWG (13.29 sq.mm) and 5 AWG (16.76 sq.mm). To keep line losses under 10% the 5 AWG would have to be selected giving 9.3% resistive line losses in this example.

Click here to visit our new automatic Line Losses Calculator.

Converting and Understanding Wire Sizes

To convert wire sizes from American Wire Gauge (AWG) to cross sectional area, mm diameter, or inches diamter click here to view our Wire Size Conversion Table

Article Last Modified: 10:32, 8th Mar 2008


Recommended Related Articles

People who read this article also enjoyed the following articles:

AWG to Square mm Wire Size Converter
Convert between AWG, inches and mm diameter, and square mm area measures of wire size
Article Last Modified: 06:45, 19th Jul 2008
storage | electric circuit

Line Losses Calculator
An automatic calculator to work out line losses in DC powered systems
Article Last Modified: 10:31, 8th Mar 2008
storage | general

24V 12V DC DC Converter
Find out how you can use a 24V battery (bank) to power 12V devices
Article Last Modified: 11:31, 24th Jul 2008
storage | electric circuit

Interconnecting Batteries for Battery Bank
Find out how best to connect batteries together into a battery bank
Article Last Modified: 13:53, 23rd Feb 2007
storage

Make a Simple Battery Status Monitor
Monitor battery status with this easy electric circuit project - no skill required!
Article Last Modified: 12:33, 16th Mar 2007
storage | electric circuit

Solar Charge Controller
Find out more about Solar Charge Controllers
Article Last Modified: 15:43, 29th Jul 2008
solar | electronics | electric circuit

Deep Cycle Batteries For Sale
Buy a deep cycle battery for your solar or wind system
Article Last Modified: 13:18, 30th Jun 2008
storage | shopping

Put Together an REUK Solar Lighting Kit
Full construction plans for solar powered shed or garage lighting using LED spotlights
Article Last Modified: 14:36, 25th Apr 2007
solar | lighting | electric circuit

Switch from Inverter to Mains Automatically
Power a circuit directly from a power inverter, but with automatic mains power back up.
Article Last Modified: 15:16, 19th Aug 2008
electric circuit | storage | general

Build a Concentrated Solar Water Heater
Plans for building a cheap advanced solar water heating system
Article Last Modified: 10:14, 12th Apr 2007
heating | solar | water

© 2006-2008 REUK - All Rights Reserved
Page Last Updated on 21st August 2008 at 01:08:27pm

Latest
Articles


40 Amp Blocking Diode 1N1190A
Find out how to use a blocking diode with a wind turbine generator
wind
13:36, 20th Aug 2008

La Rance Tidal Power Plant
Find out La Rance experimental tidal power plant in France
tidal
15:32, 19th Aug 2008

PVC Wind Turbine Blades
Learn how to make your own PVC wind turbine blades
wind
15:16, 19th Aug 2008

Shed and Garage Solar Lighting
Light your shed or garage with solar powered lighting
lighting
15:16, 19th Aug 2008

How I Built A Wind Turbine
Read how a wind turbine was built for under US$150
wind
15:16, 19th Aug 2008

10 Ways to Save Water
Find out how you can save water, energy, and money
water
15:16, 19th Aug 2008

Rainwater Toilet Flush System
Find out how to put together a complete rainwater fed toilet flushing system
water
15:16, 19th Aug 2008

Jatropha for Biodiesel Figures
Look at the financial costs of commercial Jatropha growing for Biodiesel
biomass
15:16, 19th Aug 2008



REUK Shop

Popular Items


KILL A WATT
Plug in Mains Power and Energy Monitor
£19.99 each.
Energy Saving



EFERGY HOMECO2METER
efergy homeCO2meter wireless electricity monitor
£38.99 each.
Energy Saving



240V LED SPOTLIGHT BULB
240V LED GU10 bulb. 20 x 20,000mcd white LED 1 Watt bulb
£4.99 each.
Energy Efficient Lighting



RAINWATER DIVERTER KIT
Rainwater diverter kit for standard plastic 65mm square and 68mm round downpipes
£8.99 each.
Water Conservation



300 WATT POWER INVERTER
Convert 12V DC battery power into 230 AC to power portable televisions, computers, video recorders etc. 300 Watt power rating - peak power 600 Watts
£29.99 each.
Renewable Energy System Parts



12 VOLT 3 WATT SOLAR PANEL
Waterproof 12 Volt 3 Watt Solar Panel - 199 x 136mm with fitted leads (fiberglass and resin).
£19.99 each.
Solar Power



SUNGUARD SOLAR CONTROLLER
4.5 Amp at 12 Volt solar charge controller - fully encapsulated and weatherproofed
£19.99 each.
Solar Controllers