In the UK, the voltage of mains electricity supplied to homes is approximately 242 VAC (Volts AC), but household appliances sold within the European Union (including the UK) must be designed to operate reliably when supplied with a voltage within the European statutory range - currently 207 to 253 VAC. When supplied with lower voltages (than the standard 245 VAC) appliances use less energy while functioning perfectly - sounds great, but how can you reduce the mains voltage?

Voltage Optimisation

Voltage optimisation has been used for many years in office buildings, factories, and other commercial sites in order to reduce energy usage (and of course cost). Some of these systems simply reduce the incoming mains voltage by a fixed amount - e.g. 20, 25, or 30 Volts, which is fine if you know that the mains supply is high enough and stable. Unfortunately, the actual range of supply voltages in the UK can vary - particularly in rural locations - and so this approach would not be suitable for domestic voltage optimisation.

The alternative approach is an optimiser which takes in mains voltage at one side, and outputs a fixed lower voltage from the other side which the feeds the property to be powered. This is the approach taken by the designers of VPhase, the first domestic use (single phase) voltage optimiser to come to market.

VPhase VX1 Voltage Optimiser


VPhase domestic voltage optimiser

The VPhase VX1 is designed to reduce mains voltage to a fixed level of 220 VAC - a reduction of around 10% for most homes. This in turn can offer a reduction in electricity bills for the home in which it is installed of around 10% It is housed in a unit smaller than the electricity consumer unit in the home, and fixed to the wall next to it.

If the utility supply voltage sags below 220 VAC, the VX1 voltage optimiser is automatically bypassed, so the property is always supplied with 220 VAC when the mains voltage is greater than 220 VAC, and directly with mains voltage if the mains voltage falls to below 220 VAC - i.e. if there is a brown out, the VPhase VX1 will not result in an even lower voltage getting to your appliances.

VPhase installation by qualified electrician

Electricity Savings with VPhase

The actual savings possible depend on the appliances in use. Electricity powered heating for example would cost exactly the same to run but take 10% longer to heat the air/water to the target temperature. However in testing the VPhase reduced electricity consumption by 17% for fridges and freezers, 15% for lighting (10% of the latest energy saving light bulbs), and 3-10% for TV's, HiFi's, and other entertainment systems.

Appliances with motors can use 17% less power (of the power which actually goes to the motor) - i.e. the motor in the washing machine will use less power, but the heating element will use the same amount of power, but take 10% longer to heat the water). In testing in typical homes, reductions in electricity bills of 8-11% have been found, which represent possible annual cash savings of £50 to £100+.

article correction - 28 Sept 2010
While it is correct that a heating appliance (e.g. electric kettle) will use the same total amount of energy* whatever the input voltage, if the voltage is reduced from 240 to 220 V (a reduction of about 8.3%), because power is proportional to voltage^2 across a resistive load, the corresponding *power* reduction is nearly 16%.
Time depends on power input not voltage, so it will hence take 16% longer to boil the kettle, not 8.3%. A 10% reduction in voltage would mean 19% longer.
(Taking it even further, halving the voltage would multiply the time by a factor of four).
*Assuming nothing is wasted by radiation/convection from its external surface while warming-up!


Dr Tim Dennis, University of Essex

Since most people do not want their home (or in some cases water) to take 20% longer to be heated, when the VPhase is installed, the electric heating circuits are not connected to it.

Installation of VPhase

Buying and Installing VPhase

The VPhase is available now priced at £250 + VAT plus the cost of installation. With a predicted working life of over 25 years, a VPhase should pay for itself and its installation in under 5 years, and continue to give savings from then on.

Any qualified electician can install the VPhase in an hour or two including testing etc. A short video which details the installation procedure is available here: VPhase Installation Video.

More VPhase Information

For more information on VPhase, click here to visit the official VPhase website.



Article Last Modified: 09:59, 28th Sep 2010

Comment on this Article

If you have any comments on this article, please email them to neil@reuk.co.uk.


Recommended Related Articles

People who read this article also enjoyed the following articles:

Building a Waterwheel
The story of the construction of a DIY waterwheel in the UK
Article Last Modified: 14:16, 6th Jun 2008
hydro | education

External Solid Wall Insulation
Find out about solid wall insulation applied to external walls
Article Last Modified: 13:10, 26th Apr 2012
energy efficiency | heating | general

Ecofan Woodburner Fans
Find out about Ecofan energy efficient woodburner fans
Article Last Modified: 14:10, 19th Nov 2010
heating | shopping | energy efficiency

Wattson SilverLining
Review of the new Wattson Silverlining wireless energy monitor from DIY Kyoto
Article Last Modified: 10:31, 14th Oct 2011
energy efficiency | general | shopping

Floorboard Gap Insulation Seal
Save energy by filling gaps in floorboard with this new draughtEx insulation kit
Article Last Modified: 11:32, 14th Oct 2011
energy efficiency | heating | shopping

Efficiencies of Different Types of Water Wheel
Efficiency analysis of overshot and undershot waterwheels
Article Last Modified: 12:56, 26th Feb 2011
water | education

UK Feed in Tariff to be Cut by 50 Percent
UK government announces 50% cut in feed in tariff payable on new solar PV installations
Article Last Modified: 09:56, 24th Mar 2012
solar | news | wind | general

fit PC2 Ultra Low Power PC
Find out more about the amazing fit-PC2 low power robust desktop PC
Article Last Modified: 17:10, 12th May 2009
energy efficiency | shopping | news

Geothermal Heat Pump
Find out about using ground source heat pumps to heat your home
Article Last Modified: 13:57, 29th Jan 2009
geothermal | energy efficiency

Savonius Wind Turbines
What is a savonius wind turbine - savonius (VAWT)
Article Last Modified: 12:31, 23rd Jul 2008
wind | education

© 2006-2012 REUK - All Rights Reserved
Page Last Updated on 9th May 2012 at 03:40:34pm

Latest
Articles


Wind Turbine Insurance
The importance of wind turbine insurance and what to look for
wind
12:57, 5th May 2012

Solar Insolation
A measure of the amount of solar radiation hitting the earth
solar
10:12, 5th May 2012

Virtu Hybrid Solar PV Water Heating
Find out about a new hybrid solar PV and water heating panel - Virtu
solar
13:10, 26th Apr 2012

External Solid Wall Insulation
Find out about solid wall insulation applied to external walls
energy efficiency
13:10, 26th Apr 2012

Logic Energy WindTracker
Find out more about the Logic Energy Wind Tracker
wind
08:43, 13th Apr 2012

Low Voltage Battery Disconnect Circuits
Find out more about low voltage battery disconnect (LVD) circuits - used to protect batteries
electric circuit
12:47, 31st Mar 2012

UK Feed in Tariff to be Cut by 50 Percent
UK government announces 50% cut in feed in tariff payable on new solar PV installations
solar
09:56, 24th Mar 2012

Jobs in Renewable Energy
Find a job in renewable energy and green technologies
general
20:34, 8th Mar 2012



REUK Shop

Popular Items


REUK SUPER LDR DUSK DAWN RELAY CONTROLLER
Multi-function light detector triggered light/dark dawn/dusk relay controller
£18.95 each.
Complete Circuits



KARASOULI SCC 20 CHARGE CONTROLLER
20A rated wind turbine charge controller and dump load controller with blocking diode and heatsink
£43.95 each.
Renewable Energy System Parts



SOLAR PUMP CONTROLLER WITH RELAY
Solar water heating system microprocessor controlled circuit with fitted 10A relay
£25.99 each.
Complete Circuits



REUK SUPER POULTRY LIGHTING CONTROLLER
Control up to 8 Watts of LED spotlights to stimulate egg production in birds
£29.99 each.
Complete Circuits



REUK SUPER TIMER 2
User programmable 12VDC powered 16A rated repeating relay timer. 1 second to 99 hours ON and OFF times
£23.99 each.
Complete Circuits



300 WATT POWER INVERTER
Convert 12V DC battery power into 230 AC to power portable televisions, computers, video recorders etc. 300 Watt power rating - peak power 600 Watts
£29.99 each.
Renewable Energy System Parts



CONVERTED PROGRAMMABLE DIGITAL TIMER RELAY
Mains powered programmable timer converted to low voltage with relay board
£21.99 each.
Renewable Energy System Parts



12 VOLT REGULATOR
Supply a fixed 12.0 Volt DC to your devices (up to 1 Amp output)
£4.99 each.
Complete Circuits



MR16 CERAMIC BULB HOLDER
Bulb holder for 12 Volt LED spotlight bulbs
£1.39 each.
Energy Efficient Lighting